4.16.7 PoE Alive Check Configuration

The IGS-10020PT / IGS-10020HPT PoE Switch can be configured to monitor connected PD’s status in real time via ping action.

Once the PD stops working and is without response, the IGS-10020PT / IGS-10020HPT PoE Switch is going to restart PoE port

port power, and bring the PD back to work. It will greatly enhance the reliability and reduces administrator management burden.

PD Ping Alive Check Configuration

This page provides you with how to configure PD Alive Check.The screen in Figure

4-16-8

appears.

Figure 4-16-8: PD Alive Check Configuration Screenshot

The page includes the following fields:

Object

Description

Mode

Allows user to enable or disable per port PD Alive Check function. As default value

all ports are disabled.

Ping PD IP Address

This coulumn allows user to set PoE device IP address here for system making ping

to the PoE device. Please be noted that the PD’s IP address must be set to the

same network segment as the IGS-10020PT / IGS-10020HPT PoE Switch.

Interval Time (10~300s)

This column allows user to set how long system should issue a ping request to PD

for detecting PD whether it is alive or dead. Interval time range is from 10 seconds to

300 seconds.