367

R-APS messages.

The period of the guard timer can be configured in 10 ms steps between 10 ms

and 2 seconds, with a default value of 500 ms

• WTR Time

The Wait To Restore timing value to be used in revertive switching.

The period of the WTR time can be configured by the operator in 1 minute steps

between 5 and 12 minutes with a default value of 5 minutes.

• Hold Off Time

The timing value to be used to make persistent check on Signal Fail before

switching.

The range of the hold off timer is 0 to 10 seconds in steps of 100 ms

• Version

ERPS Protocol Version - v1 or v2

• Revertive

In Revertive mode, after the conditions causing a protection switch has cleared,

the traffic channel is restored to the working transport entity, i.e., blocked on the

RPL.

In Non-Revertive mode, the traffic channel continues to use the RPL, if it is not

failed, after a protection switch condition has cleared.

• VLAN Config

VLAN configuration of the Protection Group. Click on the "VLAN Config" link to

confure VLANs for this protection group.

PRL Configuration:

Object

Description

• PRL Role

It can be either RPL owner or RPL Neighbour.

• PRL Port

This allows to select the east port or west port as the RPL block.

• Clear

If the owner has to be changed, then the clear check box allows to clear the RPL

owner for that ERPS ring.

Instance Command:

Object

Description

• Command

Administrative command. A port can be administratively configured to be in either

manual switch or forced switch state.

• Port

Port selection - Port0 or Port1 of the protection Group on which the command is

applied.

Instance State:

Object

Description

Advertising