User’s Manual of IGS-10020PT / IGS-10020HPT

344

Retry Count (1~5)

This column allows user to set how many times system retries ping to PD. For

example, if we set count 2, the meaning is that if system retries ping to the PD and

the PD doesn’t response continuously, the PoE port will be reset.

Action

Allows user to set which action will be applied if the PD is without any response. The

IGS-10020PT / IGS-10020HPT PoE Switch offers 3 actions as follows:

PD Reboot: It means system will reset the PoE port that is connected to the

PD.

Reboot & Alarm: It means system will reset the PoE port and issue an alarm

message via Syslog, SMTP.

Alarm: It means system will issue an alarm message via Syslog, SMTP.

Reboot Time (30~180s)

This column allows user to set the PoE device rebooting time, due to there are so

many kinds of PoE devices on the market and they have different rebooting times.

The PD Alive-check is not a defining standard, so the PoE device on the market

doesn’t report reboots done information to the IGS-10020PT / IGS-10020HPT PoE

Switch, so user has to make sure how long the PD will be finished to boot, and then

set the time value to this column.

System is going to check the PD again according to the reboot time. If you cannot

make sure precisely what booting time is, we suggest you to set it longer.

Buttons

: Click it to save changes.

: Click it to reset configuration which doesn’t want to be saved yet.