ProSoft Technology MVI46-DNP User Manual

Page 123

Advertising
background image

Reference MVI46-DNP

♦ SLC Platform

Master/Slave Communication Module

ProSoft Technology, Inc.

Page 123 of 143

August 23, 2007

Object

Request

Response

Obj Var Description

Func
Codes

Qual
Codes
(hex)

Func
Codes

Qual
Codes
(hex)

Data
Size
(bits)

Notes

22 0 Counter

Change

Event - All
Variations

1 06,

07,

08

Master will not
generate a
request for this
variation.

1

32-Bit Counter
Change Event
Without Time

129, 130

17, 28

40

Master will
process this
variation.

2

16-Bit Counter
Change Event
Without Time

129, 130

17, 28

24

Master will
process this
variation.

3

32-Bit Delta Counter
Change Event
Without Time

40

4

16-Bit Delta Counter
Change Event
Without Time

24

5

32-Bit Counter
Change Event With
Time

88

6

16-Bit Counter
Change Event With
Time

72

7

32-Bit Delta Counter
Change Event With
Time

88

8

16-Bit Delta Counter
Change Event With
Time

72

23 0 Frozen

Counter

Event - All
Variations

1

32-Bit Frozen
Counter Event
Without Time

40

2

16-Bit Frozen
Counter Event
Without Time

24

3

32-Bit Frozen Delta
Counter Event
Without Time

40

4

16-Bit Frozen Delta
Counter Event
Without Time

24

5

32-Bit Frozen
Counter Event With
Time

88

6

16-Bit Frozen
Counter Event With
Time

72

Advertising