84

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

port

State
Change+

“port.1 in

SWITCH

diag185

(

ip=

xxx.20.67.185

) is now

Available (status-state
changed from offline to
online)”

The port on the switch is
now available.

port

State
Change-

Red

Y

A port on switch2 has
logged out of the Fabric
connection and has gone
offline.

1. Verify cables, GBICs, and

connections along the FC
path.

2. Check the Storage

Automated Diagnostic
Environment SAN
Topology GUI to identify
failing segment of the
data path.

3. Verify the correct FC

switch configuration.

enclosure

Statistics

“Statistics about

switch

d2-swb1

(ipxxx.0.0.41)

10002000007a609”

TABLE 7-2

Storage Automated Diagnostic Environment Event Grid for 2 GBit Switches (Continued)

Component

EventT

ype

Se

verity

Action

Description