Verify the fan state with fru stat, Replace the power cooling unit, if necessary, Verify power cooling unit state in fru stat – Sun Microsystems 6900 User Manual

Page 118: Replace power cooling unit, if necessary, Sun proprietary/confidential: internal use only

Advertising
background image

98

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

power.fan

Alarm-

Red

Y

The state of a fan on the
Sun StorEdge T3+ array
is not optimal.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify the fan state

with

fru stat.

3. Replace the power

cooling unit, if
necessary.

power.output

Alarm-

Red

Y

The state of the power in
the Sun StorEdge T3+
array power cooling unit
is not optimal.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify power cooling

unit state in fru stat.

3. Replace power

cooling unit, if
necessary.

power.temp

Alarm-

Red

Y

The state of the
temperature in the Sun
StorEdge T3+ array
power cooling unit is
either too high or is
unknown.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify that the power

cooling unit state is in

fru stat

3. Replace the power

cooling unit, if
necessary.

log

Alarm

Red

Y

This event includes all
important errors found.

Check the

/messages

file for appropriate
action.

time_diff

Alarm

Yellow

Y

Fix the date and time on
the Sun StorEdge T3+
array using the date
command. The date and
time should be the same
as the monitoring host.

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description

Action