140

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

To Use the Sun StorEdge T3+ Array Failover Driver GUI

Note –

The Sun StorEdge T3+ Array Failover Driver GUI is limited to the Sun

StorEdge 3900 series systems. You must use the CLI for the Sun StorEdge 6900 series
systems.

1. Make sure the Sun StorEdge T3+ Array failover driver is loaded.

From the Microsoft Windows 2000 Advanced Server GUI, click Administrative
Tools -> Computer Management -> Software Environment.

2. Ensure the "Jafo" driver is in a Running and OK state.

3. Launch the Sun StorEdge T3+ Array Failover Driver GUI using instructions found

in “Launching the Sun StorEdge T3+ Array Failover Driver GUI” on page 138.

The Multipath Configurator window is displayed.

A healthy Sun StorEdge 3900 series system has a solid line connecting the HBA to
the storage, as shown in

FIGURE 10-3

.

FIGURE 10-3

Healthy Sun StorEdge 3900 series system, shown using Multipath
Configurator

Note –

Note the connection between the two arrays, indicating that the back end

loop is being used.