Check the sun storedge t3+ network connection, Check whether any other secfg utility is running, If an secfg utility is running, allow it to finish – Sun Microsystems 6900 User Manual

Page 192: Sun proprietary/confidential: internal use only

Advertising
background image

172

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Common to Sun
StorEdge T3+ array

• The Sun StorEdge T3+ array is not
of T3B type, so it aborts operations.

t3config

utilities are supported

only in the Sun StorEdge T3+ array;
the

t3config

utilities are not

supported on Sun StorEdge T3+
arrays with 1.xx firmware.

1. Refer to the T3 default/custom

configuration table in the Sun
StorEdge 3900 and 6900 Series 2.0
Reference and Service Guide.

2. Use

showt3-n t3_name

to

display the present configuration.

3. Check the Sun StorEdge T3+

firmware version (it should be
version 2.01.00 or higher).
Upgrade if required.

Common to Sun
StorEdge T3+ array

• No response received from

$t3_name

. Aborting operation.

1. Check the Sun StorEdge T3+

network connection.

2. Check with Ping

$t3_name

command to determine if the Sun
StorEdge T3+ array is operating.

Common to Sun
StorEdge T3+ array

volslice

is not enabled on this Sun

StorEdge T3+ array.

Check the T3+ firmware (2.01.00 or
higher) to make sure volume slicing
is allowed with this version of
firmware.

Common to Sun
StorEdge T3+ array

• Error while opening the Sun
StorEdge T3+ array.
• Cannot open after resetting the Sun
StorEdge T3+ array.

1. Check the Sun StorEdge T3+

master and alternate master
network connection.

2. Check with Ping

$t3_name

command to determine if the Sun
StorEdge T3+ array is operating.

checkt3config

The

vol init

command is being

executed by another user. Additional

vol

commands cannot run.

1. Check whether any other

secfg

utility is running.

2. If an

secfg

utility is running,

allow it to finish.

checkt3config

An error occurred while the

checkt3config

command was

checking the process list, causing the

t3_name

to abort.

Check whether any other

secfg T3+

or native Sun StorEdge

T3+ array commands are being
executed on that particular Sun
StorEdge T3+ array.

checkt3config

Snapshot configuration files are not
present. Unable to check
configuration.

1. Verify that the snapshot files are

saved and have read permissions
in the

/opt/SUNWsecfg/etc/t3name

/

directory.

2. If the snapshot files are not

available, create them using the

savet3config

command.

TABLE B-3

Sun StorEdge T3+ Array Error Messages (Continued)

Source of Error Message

Cause of Error Message

Suggested Corrective Action

Advertising
This manual is related to the following products: