Fru tests available for the t1 or t2 data path fru, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 113

Advertising
background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

93

Sun Proprietary/Confidential: Internal Use Only

FRU Tests Available for the T1 or T2 Data Path FRU

Running the tests from the Storage Automated Diagnostic Environment GUI guides
you in discovering the failed FRU. Refer to Chapter 5 of the Storage Automated
Diagnostic Environment User’s Guide
for instructions on how to run tests.

Run the

switchtest

to test the switches.

Run the

linktest

to test the T1 or T2 connections.

After a test has completed its run, an email message similar to the message in

FIGURE 8-4

is sent to the specified email recipient.

FIGURE 8-4

Example Link Test Text Output from the Storage Automated Diagnostic
Environment

running on diag.xxxxx.xxx.com

linktest started on FC interconnect: switch to switch

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:21:26 diag209 Storage Automated Diagnostic Environment: MSGID

6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC Cable from switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8

Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:22:11 diag209 Storage Automated Diagnostic Environment: MSGID

6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Insert a NEW FC GBIC into switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8

Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8

Estimated test time 14 minute(s)

01/30/02 11:25:12 diag209 Storage Automated Diagnostic Environment: MSGID

4001 switchtest.WARNING

switch0: "Maximum transfer size for a FABRIC port is 200. Changing transfer

size 2000 to 200"

switchtest completed successfully

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Restore ORIGINAL FC Cable into switch: 100000c0dd00b682, port: 8

Suspect ORIGINAL FC GBIC in switch: 100000c0dd00b682, port: 8

Retest to verify FRU replacement.

linktest completed on FC interconnect: switch to switch

Advertising
This manual is related to the following products: