Manually halting the i/o, To quiesce the i/o, Determine the path you want to disable – Sun Microsystems 6900 User Manual

Page 37: Type, To unconfigure the c2 path, To unconfigure the, Sun proprietary/confidential: internal use only

Advertising
background image

Chapter 2

General Troubleshooting Procedures

17

Sun Proprietary/Confidential: Internal Use Only

Note that in the

Class

and

State

fields, the virtualization engines are presented as

two primary

ONLINE

devices. The current Sun StorEdge Traffic Manager software

design does not enable you to manually halt the I/O (that is, you cannot perform a
failover to the secondary path) when only primary devices are present.

Manually Halting the I/O

As an alternative to using the Sun StorEdge Traffic Manager (MPxIO) software, you
can manually halt the I/O using one of two methods:

Quiesce the I/O

Unconfigure the

c2

path

These methods are explained in the following sections.

To Quiesce the I/O

1. Determine the path you want to disable.

2. Type:

To Unconfigure the

c2

Path

1. Type:

# cfgadm -c unconfigure

device

# cfgadm -al

Ap_Id Type Receptacle Occupant Condition

c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t6d0 CD-ROM connected configured unknown
c2 fc-fabric connected configured unknown
c2::210100e08b23fa25 unknown connected unconfigured unknown
c2::2b000060220041f4 disk connected configured unknown
c3 fc-fabric connected configured unknown
c3::210100e08b230926 unknown connected unconfigured unknown
c3::2b000060220041f9 disk connected configured unknown
c4 fc-private connected unconfigured unknown
c5 fc connected unconfigured unknown