Troubleshooting the Fibre Channel (FC) Links

49

Sun Proprietary/Confidential: Internal Use Only

Troubleshooting the A2 or B2 FC Link

The A2 or B2 link is the FC link from the first switch to the virtualization engine.
This link exists in the Sun StorEdge 6900 Series only. An error with the FC link can
cause a path to go offline.

FIGURE 5-6

and

FIGURE 5-7

are examples of A2 or B2 Link Notification Events.

FIGURE 5-6

A2 or B2 FC Link Host-Side Event

From root Tue Jan 8 18:39:48 2002

Date: Tue, 8 Jan 2002 18:39:47 -0700 (MST)

Message-Id: <[email protected]>

From: Storage Automated Diagnostic Environment.Agent

Subject: Message from ’diag.xxxxx.xxx.com’ (2.0.B2.002)

Content-Length: 2742

You requested the following events be forwarded to you from

’diag.xxxxx.xxx.com’.

Site : FSDE LAB Broomfield CO

Source : diag226.xxxxx.xxx.com

Severity : Normal

Category : Message Key: message:diag.xxxxx.xxx.com

EventType: LogEvent.driver.Fabric_Warning

EventTime: 01/08/2002 17:34:47

Found 1 ’driver.Fabric_Warning’ warning(s) in logfile: /var/adm/messages

on diag.xxxxx.xxx.com (id=80fee746):

Info: Fabric warning

Jan 8 17:34:36

WWN:2b000060220041f4

diag.xxxxx.xxx.com fp: [ID 517869

kern.warning] WARNING: fp(0): N_x Port with D_ID=108000,

PWWN=2b000060220041f4 disappeared from fabric

<snip>

multipath status: degraded, path /pci@6,4000/SUNW,qlc@2/fp@0,0 (fp0) to

target address: 2b000060220041f4,1 is offline

Jan 8 17:34:55 WWN:2b000060220041f4 diag.xxxxx.xxx.com

mpxio: [ID 779286 kern.info] /scsi_vhci/

ssd@g29000060220041f96257354230303052 (ssd18)

multipath status: degraded, path /pci@6,4000/SUNW,qlc@2/fp@0,0 (fp0) to

target address: 2b000060220041f4,0 is offline