Check the hba, Isolate the components in the path, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 169

Advertising
background image

Chapter 11

Example of Fault Isolation

149

Sun Proprietary/Confidential: Internal Use Only

The primary path to

Drive F:

failed. The alternate path is currently handling all

of the I/O.

3. Check the HBA

Using the HBA utility (Qlogic SANblade in this example), confirm the fault.

FIGURE 11-3

Fault Confirmation Using QLogic SunBlade

4. Isolate the components in the path.

The components in the path are the HBA, the cable, the switch-side GBIC, and the
Sun StorEdge network FC switch itself.

To isolate all components, use a combination of the Storage Automated Diagnostic
Environment and the HBA utility (QLogic SunBlade).

Note –

If no HBA utility is present, or if the utilities do not offer diagnostics, a best

guess effort will have to suffice. Storage Automated Diagnostic Environment cannot
test HBAs on Microsoft Windows 2000 hosts at this time.