Run the showswitch(1m) command for sw2a and sw2b, Code example 9-5, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 141

Advertising
background image

Chapter 9

Troubleshooting Virtualization Engine Devices

121

Sun Proprietary/Confidential: Internal Use Only

a. If no failures occur, the command exits with no output.

b. If failures occur, you might see one of the following messages:

CODE EXAMPLE 9-5

Sun StorEdge T3+ Array Failure Codes

The message return code 513 indicates that the Sun StorEdge T3+ array did not require
a failback. The message return code 586 indicates that the Sun StorEdge T3+ array
failback could not be completed because the primary path could not be reached.

3. If you encounter the return code 586, check the switches

sw2a

and

sw2b

and make

sure the ports associated with the Sun StorEdge T3+ array and virtualization
engines are online.

In this example:

a.

t3b0

should be plugged in to port 2 (on a 1 Gbit switch) of both

sw2a

and

sw2b

(port 1 on a 2 Gbit switch)

b. The virtualization engine should be plugged in to port 1 (on a 1 Gbit switch) of

the same two switches (port 0 on a 2 Gbit switch).
Refer to the Sun StorEdge 3900 and 6900 Series 2.0 Reference and Service Guide
to
determine which switch ports are used for each component.

4. Run the

showswitch

(1M) command for

sw2a

and

sw2b

.

5. Look at the output sections "Port Status" and "Name Server" to see if the ports are

online. The output will look like that in

CODE EXAMPLE 9-6

if there are no

problems.

# /opt/SUWNsecfg/bin/failbackt3path -n t3b0

MultiPath failback command failed. Returned Result = 513

# /opt/SUWNsecfg/bin/failbackt3path -n t3b0

MultiPath failback command failed. Returned Result = 586