Notification events, Figure81 storage service processor event, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 109

Advertising
background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

89

Sun Proprietary/Confidential: Internal Use Only

Notification Events

FIGURE 8-1

shows a typical port failure event

.

FIGURE 8-1

Storage Service Processor Event

Site : Lab 3286 - DSQA1 Broomfield

Source : diag.xxxxx.xxx.com

Severity : Error (Actionable)

Category : Switch

DeviceId : switch:100000c0dd00b682

EventType: StateChangeEvent.M.port.8

EventTime: 01/30/2002 11:17:22

’port.8’ in SWITCH diag209-sw2a (ip=192.168.0.32) is now Not-Available

(status-state changed from ’Online’ to ’Offline’):

INFORMATION:

A port on the switch has logged out of the fabric and gone offline

PROBABLE-CAUSE:

1. Verify cables, GBICs and connections along Fibre Channel path

2. Check Storage Automated Diagnostic Environment SAN Topology GUI to

identify failing segment of the data path

3. Verify correct FC switch configuration

----------------------------------------------------------------------

Site : Lab 3286 - DSQA1 Broomfield

Source : diag.xxxxx.xxx.com

Severity : Warning

Category : Switch

DeviceId : switch:100000c0dd00b682

EventType: LogEvent.MessageLog

EventTime: 01/30/2002 11:17:22

Change in Port Statistics on switch diag209-sw2a (ip=192.168.0.32):

Port-8: Received 9746 ’InvalidTxWds’ in 0 mins (value=9805 )