Figure118 successful switch test results, Recover the problem with the gbic or the switch, A. recable the link between the hba and switch – Sun Microsystems 6900 User Manual

Page 173: Sun proprietary/confidential: internal use only

Advertising
background image

Chapter 11

Example of Fault Isolation

153

Sun Proprietary/Confidential: Internal Use Only

The first run failed, indicating a problem with either the GBIC or with the Sun
StorEdge network FC switch.

To further isolate the problem, a new GBIC was inserted into the port, the loopback
connector was re-inserted, and the same test was run a second time.

FIGURE 11-8

Successful Switch Test Results

On this pass, the test was successful. This indicates that the problem was most likely
the switch-side GBIC, which was replaced.

6. Recover the problem with the GBIC or the switch.

a. Recable the link between the HBA and switch.

b. Use the Sun StorEdge T3+ Array Failover Driver GUI for the Sun StorEdge 3900

series system, or the CLI for the 6900 series, to recover the multipathing.