Troubleshooting the a4 or b4 fc link, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 80

Advertising
background image

60

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Troubleshooting the A4 or B4 FC Link

The A4 or B4 link is the FC link from the switch to the Sun StorEdge T3+ array.

If a problem occurs with the A4 or B4 FC link:

In a Sun StorEdge 3900 series system, the Sun StorEdge T3+ array will fail over.

In a Sun StorEdge 6900 series system, no Sun StorEdge T3+ array will fail over,
but an error with the FC link can cause a path to go offline.

FIGURE 5-11

and

FIGURE 5-12

are examples of A4 or B4 Link Notification Events.

FIGURE 5-11

A4 or B4 FC Link Data-Host Notification

Site : FSDE LAB Broomfield CO
Source : diag.xxxxx.xxx.com
Severity : Warning
Category : Message
DeviceId : message:diag.xxxxx.xxx.com
EventType: LogEvent.driver.MPXIO_offline
EventTime: 01/29/2002 14:28:06

Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80e4aa60):

<snip>

----------------------------------------------------------------------
Site : FSDE LAB Broomfield CO
Source : diag.xxxxx.xxx.com
Severity : Warning
Category : Message
DeviceId : message:diag.xxxxx.xxx.com
EventType: LogEvent.driver.Fabric_Warning
EventTime: 01/29/2002 14:28:06

Found 1 ’driver.Fabric_Warning’ warning(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80e4aa60):
INFORMATION:
Fabric warning

<snip>

status of hba /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0:devctl on
diag.xxxxx.xxx.com changed from CONNECTED to NOT CONNECTED
INFORMATION:
monitors changes in the output of luxadm -e port

Found path to 20 HBA ports
/devices/sbus@2,0/SUNW,socal@d,10000:0 NOT CONNECTED