Sun proprietary/confidential: internal use only, Primary data paths to the alternate master, Figure 2-2 – Sun Microsystems 6900 User Manual

Page 32: Figure 2-3

Advertising
background image

12

Sun StorEdge 3900 and 6900 2.0 Series Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Currently, one 10-Gbyte VLUN is created from each physical LUN, for a total of two
VLUNs. The Sun StorEdge 6900 series has four possible physical paths to each Sun
StorEdge T3+ array volume (LUN).

Refer to

FIGURE 2-2

, which illustrates primary data paths to the alternate master, and

FIGURE 2-3

, which illustrates the primary data paths to the master Sun StorEdge T3+

array.

FIGURE 2-2

Primary Data Paths to the Alternate Master

Host with HBA-0 and HBA-1

LUN0 - 10G

Active-MPDrive 0

LUN1 - 10G

Active-MPDrive 1

Switch

Virtualization

Engine (2)

Virtualization

Engine (1)

Switch

LUN1 - 10G

Active-MPDrive 1

LUN0 - 10G

Active-MPDrive 0

LUN0 - 500G

Active-Master

LUN1 - 500G

Passive -

Alternate Master

LUN0 - 500G

Passive-Master

LUN1 - 500G

Active -

Alternate Master

Switch

Switch

Logical Multipath Drive

MPDrive 0

Logical Multipath Drive

MPDrive 1

T3ES

(Master) (0A - 1P)

(Alternate Master)

(1A - 0P)

SAN

Database

MPDrive

Carved LUNs

Masking

Storage I/O and

Virtualization Engine Communications Traffic

Advertising