Verifying the Data Host

The following example shows an error in the A1 or B1 FC link, which can cause a
path to go offline in the multipathing software.

CODE EXAMPLE 5-1

luxadm

(1M) Display

# /usr/sbin/luxadm display

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

DEVICE PROPERTIES for disk: /dev/rdsk/

c6t29000060220041F96257354230303052d0s2

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: SESS01

WWN(Node): 2a000060220041f4

WWN(Port A): 2b000060220041f4

WWN(Port B): 2b000060220041f9

Revision: 080C

Serial Num: Unsupported

Unformatted capacity: 102400.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

/devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller /devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address 2b000060220041f9,0

Class primary

State OFFLINE

Controller /devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address 2b000060220041f4,0

Class primary

State ONLINE

...