Chapter 9

Troubleshooting Virtualization Engine Devices

113

Sun Proprietary/Confidential: Internal Use Only

FC Link Error Status Report

The virtualization engine’s host-side and device-side interfaces provide statistical
data for the counts listed in

TABLE 9-4

.

To Check the FC Link Error Status Manually

The Storage Automated Diagnostic Environment, which runs on the Storage Service
Processor, monitors the FC link status of the virtualization engine. The virtualization
engine must be power-cycled to reset the counters. Therefore, you should manually
check the accumulation of errors during a fixed period of time. To check the status
manually, follow these steps:

1. Use the

svstat

command to take a reading, as shown in

CODE EXAMPLE 9-1

.

A status report for the host-side and device-side ports is displayed.

2. Within the next few minutes, take another reading.

The number of new errors that occurred within that time frame represents the
number of link errors.

TABLE 9-4

Virtualization Engine Statistical Data

Count Type

Description

Link failure count

The number of times the virtualization engine’s frame manager
detects a nonoperational state or other failure of N port
initialization protocol.

Loss of
synchronization
count

The number of times that the virtualization engine detects a loss in
synchronization.

Loss of signal count

The number of times that the virtualization engine’s frame manager
detects a loss of signal.

Primitive sequence
protocol error

The number of times that the virtualization engine’s frame manager
detects N port protocol errors.

Invalid transmission
word

The number of times that the virtualization engine’s 8-bit and 10-bit
decoder does not detect a valid 10-bit code.

Invalid cyclic
redundancy code
(CRC) count

The number of times that the virtualization engine receives frames
with a defective CRC and a valid

EOF

. A valid

EOF

includes

EOFn

,

EOFt

, or

EOFdti

.

Advertising