Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 36

Advertising
background image

16

Sun StorEdge 3900 and 6900 2.0 Series Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Multipathing Options in the Sun
StorEdge 6900 Series

The presence of the virtualization engine makes multipathing in a Sun StorEdge
6900 series environment challenging.

Unlike Sun StorEdge T3+ array and Sun StorEdge network FC switch-8 and switch-
16 switch installations (which present primary and secondary pathing options), the
virtualization engines present only primary pathing options to the data host. The
virtualization engines handle all failover and failback operations and mask those
operations from the multipathing software on the data host.

The following example illustrates a Sun StorEdge Traffic Manager (MPxIO) software
problem on a Sun StorEdge 6900 series system.

# /usr/sbin/luxadm display

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

DEVICE PROPERTIES for disk: /dev/rdsk/

c6t29000060220041F96257354230303052d0s2

Status(Port A): O.K.

Status(Port B): O.K.

Vendor: SUN

Product ID: SESS01

WWN(Node): 2a000060220041f4

WWN(Port A): 2b000060220041f4

WWN(Port B): 2b000060220041f9

Revision: 080C

Serial Num: Unsupported

Unformatted capacity: 102400.000 MBytes

Write Cache: Enabled

Read Cache: Enabled

Minimum prefetch: 0x0

Maximum prefetch: 0x0

Device Type: Disk device

Path(s):

/dev/rdsk/c6t29000060220041F96257354230303052d0s2

/devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller /devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address 2b000060220041f4,0

Class primary

State ONLINE

Controller /devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address 2b000060220041f9,0

Class primary

State ONLINE

Advertising