70

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Component

EventT

ype

Se

verity

Action

Description

Inf

ormation

ifptest

Diagnostic
Test-

Red

Y

ifptest

(diag240) on the

host failed.

Check Test Manager for
failure details.

qlctest

Diagnostic
Test-

Red

qlctest

(diag240) on the

host failed.

Check Test Manager for
failure details.

socal

test

Diagnostic
Test-

Red

socaltest

(diag240) on

the host failed.

Check Test Manager for
failure details.

enclosure

PatchInfo

New patch and package
information were
generated.

Send changes to the output
of

showrev -p

and

pkginfo -|

.

enclosure

backup

The Agent was backed up.

Backs up the configuration
file of the Agent.

disk_
capacity

Alarm

Yellow

Y

Detected that

/var/opt/SUNWstade

is

at or above 98% capacity
by typing:

/usr/sbin/df -k /

var/opt/SUNWstade

Remove unused files and
directories to free up space.
Use a larger disk for

/var/opt/SUNWstade

disk_
capacity_
okay

Alarm

Detected that

/var/opt/SUNWstade

is

now below 98% capacity
by typing:

/usr/sbin/df -k /

var/opt/SUNWstade

No action is required.

TABLE 6-1

Storage Automated Diagnostic Environment Event Grid for the Host (Continued)