Quiescing the I/O on the A3 or B3 Link

1. Determine the path you want to disable.

2. Disable the path by typing the following:

3. Verify that the path is disabled:

Steps 1 and 2 halt I/O only up to the A3 to B3 link. I/O continues to move over the
T1 and T2 paths, as well as the A4 to B4 links to the Sun StorEdge T3+ array.

Suspending the I/O on the A3 to B3 Link

Use one of the following methods to suspend I/O while the failover occurs:

Stop all customer applications that are accessing the Sun StorEdge T3+ array.

Manually pull the link from the Sun StorEdge T3+ array to the switch and wait
for a Sun StorEdge T3+ array LUN failover.

After the failover occurs, replace the cable and proceed with testing and FRU
isolation.

After testing is complete and any FRU replacement is finished, return the
controller state back to the default by using the virtualization engine failback
command.

Caution –

This action will cause SCSI errors on the data host and a brief suspension

of I/O while the failover occurs.

# /usr/bin/vxdmpadm disable ctlr=<c

n

>

# /usr/bin/vxdmpadm listctlr all