Chapter 5

Troubleshooting the Fibre Channel (FC) Links

53

Sun Proprietary/Confidential: Internal Use Only

5. If the switch and the GBIC show no errors, replace the remaining components in

the following order:

a. Replace the virtualization engine-side GBIC, recable the link, and monitor the

link for errors.

b. Replace the cable, recable the link, and monitor the link for errors.

c. Replace the virtualization engine, restore the virtualization engine settings,

recable the link, and monitor the link for errors.

Note –

The procedures for restoring virtualization engine settings are in the Sun

StorEdge 3900 and 6900 Series 2.0 Reference and Service Guide.

6. Return the path to production.