Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

enclosure

QuiesceStart

Quiesce has started on a
Sun StorEdge T3+ array.

controller

Topology-

Red

Y

’The Sun StorEdge T3+
array has reported that a
controller was removed
from the chassis.

Replace the controller
within the 30-minute
power shutdown
timeframe.

disk

Topology-

Red

Y

The Sun StorEdge T3+
array has reported a disk
has been removed from
the chassis.

Replace the disk within
the 30-minute power
shutdown timeframe.

interface.
loopcard

Topology-

Red

Y

The Sun StorEdge T3+
array has reported that a
loopcard has been
removed from the
chassis.

Replace the loopcard
within the 30-minute
power shutdown
timeframe.

power

Topology

Red

Y

The Sun StorEdge T3+
array has reported that a
power cooling unit PCU
has been removed from
the chassis.

Replace the PCU within
the 30-minute shutdown
timeframe.

controller

State
Change+

The status of the
controller has changed
from disabled to ready-
enabled.

disk

State
Change+

The status of the disk has
changed from fault-
disabled to ready-
enabled.

interface.
loopcard

State
Change+

The Sun StorEdge T3+
array has reported that a
loopcard has been
replaced or brought back
online.

volume

State
Change+

The status of the LUN in
a Sun StorEdge T3+ array
has changed from
unmounted to mounted
and is now available.

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description

Action