To isolate the a1 or b1 fc link, Quiesce the i/o on the a1 or b1 fc link path, Break the connection by uncabling the link – Sun Microsystems 6900 User Manual

Page 68: Insert a loopback connector into the switch port, Rerun switchtest, B. if switchtest fails again, replace the switch, Insert a loopback connector into the hba, Run qlctest, A. if the qlctest test fails, replace the hba, B. if the qlctest test passes, replace the cable

Advertising
To isolate the a1 or b1 fc link, Quiesce the i/o on the a1 or b1 fc link path, Break the connection by uncabling the link | Insert a loopback connector into the switch port, Rerun switchtest, B. if switchtest fails again, replace the switch, Insert a loopback connector into the hba, Run qlctest, A. if the qlctest test fails, replace the hba, B. if the qlctest test passes, replace the cable | Sun Microsystems 6900 User Manual | Page 68 / 204 To isolate the a1 or b1 fc link, Quiesce the i/o on the a1 or b1 fc link path, Break the connection by uncabling the link | Insert a loopback connector into the switch port, Rerun switchtest, B. if switchtest fails again, replace the switch, Insert a loopback connector into the hba, Run qlctest, A. if the qlctest test fails, replace the hba, B. if the qlctest test passes, replace the cable | Sun Microsystems 6900 User Manual | Page 68 / 204