Verify the loopcard state with fru stat, Replace the loopcard if necessary, Reenable the disk if possible – Sun Microsystems 6900 User Manual

Page 117: Replace the disk, if necessary, Run refresh -s to verify the battery state, Replace the battery, if necessary, Sun proprietary/confidential: internal use only

Advertising
background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

97

Sun Proprietary/Confidential: Internal Use Only

interface.
loopcard.cable

Alarm-

Red

Y

The Sun StorEdge T3+
array has reported that a
loopcard is in a failed
state.

Possible Drive Status
Messages:

Value Description
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disabled
5 Drive has been
replaced
7 Invalid system area on
drive
9 Drive not present
D Drive disabled; drive is
being reconstructed
S Drive substituted

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify the loopcard

state with fru stat.

3. Verify the matching

firmware with the
other loopcard.

4. Reenable the loopcard

if possible (

enable u

(encid)|[1|2]

).

5. Replace the loopcard

if necessary.

6. Reenable the disk if

possible

7. Replace the disk, if

necessary.

power.battery

Alarm-

Red

Y

The state of the batteries
in the Sun StorEdge T3+
array is not optimal.

Possible causes are:
• The voltage level on
the power supply and
the battery have moved
out of acceptable
thresholds.
• The internal power
cooling unit (PCU)
temperature has
exceeded acceptable
thresholds.
• A PCU fan has failed.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Run

refresh -s

to

verify the battery
state.

3. Replace the battery, if

necessary.

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description