Replace the disk if necessary, Verify loopcard state with fru stat, Verify matching firmware with other loopcard – Sun Microsystems 6900 User Manual

Page 124: Replace the loopcard, if necessary, Sun proprietary/confidential: internal use only

Advertising
background image

104

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

disk

State
Change-

Red

Y

The Sun StorEdge T3+
array has reported that a
disk has failed.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify the disk state

with

vol_stat

,

fru_stat

, and

fru_list

.

Drive Status Messages:
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disabled
5 Drive has been
replaced
7 Invalid system area on
drive
9 Drive not present
D Drive disabled; is
being reconstructed
S Drive substituted

3. Replace the disk if

necessary.

interface.
loopcard

State
Change-

Red

Y

The Sun StorEdge T3+
array has indicated that
the loopcard is no longer
in an optimal state.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify loopcard state

with

fru stat

.

3. Verify matching

firmware with other
loopcard.

4. Reenable the

loopcard, if possible
with: (enable
u(encid)|[1|2|])

5. Replace the loopcard,

if necessary.

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description

Action