Check the power supply and cables, Replace pcu, if necessary, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 125

Advertising
background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

105

Sun Proprietary/Confidential: Internal Use Only

volume

State
Change-

Red

Y

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify the status of the

LUNs with

vol_mode

or

vol

_stat

.

Drive Status Messages:
0 Drive mounted
2 Drive present
3 Drive is spun up
4 Drive is disabled
5 Drive has been
replaced
7 Invalid system area on
drive
9 Drive not present
D Drive disabled; is
being reconstructed
S Drive substituted

power

State
Change-

Red

Y

The Sun StorEdge T3+
array has reported that a
power cooling unit has
been disabled.

A PCU failure can
happen due to:
1. Power loss
2. The PCU fails
3. The power switch is
disrupted.

1. Check the power

supply and cables.

2. Replace PCU, if

necessary.

enclosure

Statistics

Displays statistics about
the Sun StorEdge T3+
array enclosure

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description

Action