Check the status of the slicd daemon, Check the power on the virtualization engine, Replace the virtualization engine, if necessary – Sun Microsystems 6900 User Manual

Page 154: Sun proprietary/confidential: internal use only

Advertising
background image

134

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

oob.slicd

Comm_
Lost

Down

The virtualization engine
failed to execute

slicd

command.

1. Check the status of the slicd

daemon.

2. Check the power on the

virtualization engine.

3. Make sure the virtualization

engine is booted correctly.

4. Verify that the TCP/IP

settings on the virtualization
engine are correct.

5. Check the T3 message log for

failover conditions in the Sun
StorEdge T3+ array.

6. Replace the virtualization

engine, if necessary.

oob.
command

Comm_
Lost

Down

Invalid command or

slicd

daemon problem.

1. Check the status of the slicd

daemon.

2. Check the power on the

virtualization engine.

3. Make sure the virtualization

engine is booted correctly.

4. Verify that the TCP/IP

settings on the virtualization
engine are correct.

5. Check the T3 message log for

failover conditions in the Sun
StorEdge T3+ array.

6. Replace the virtualization

engine, if necessary.

TABLE 9-5

Storage Automated Diagnostic Environment Event Grid for Virtualization Engine (Continued)

Component

EventType

Severity

Information

Required
Action