Figure114 diagnostics using qlogic sunblade, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 170

Advertising
background image

150

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

FIGURE 11-4

Diagnostics Using QLogic SunBlade

In this example, the HBA-to-switch cable was removed temporarily and a loopback
connector was inserted into the HBA. The Qlogc SANblade LoopBack diagnostics
were then run. The HBA passed the tests.

Note –

The next components that can be isolated are the switch-side GBIC and the

Sun StorEdge network FC switch itself.

For these components, you can launch the tests using the Storage Automated
Diagnostic Environment Diagnose -> Tests -> Test From Topology functionality.

5. Again, temporarily remove the cable from the switch port in question, insert a

loopback connector plug and run the switch port diagnostics.

The first run will test the switch-side GBIC as well as the Sun StorEdge network FC
switch.