Backup the drive data, Format the drives using mode 14, Create a new mirror drive – Sun Microsystems 6900 User Manual

Page 177: Restore the data, Sun proprietary/confidential: internal use only

Advertising
background image

Appendix A

Virtualization Engine References

157

Sun Proprietary/Confidential: Internal Use Only

70021

The drive is offline.

If the change was unintentional, check the
condition of the drives.

70022

The virtualization engine is offline.

If the change was unintentional, check the
condition of the drives.

70023

The drive is unresponsive.

Check the condition of drives.

70024

For the Sun StorEdge T3+ array pack, the master
virtualization engine has detected the partner
virtualization engine’s IP Address.

No action is needed.

70025

For Sun StorEdge T3+ array pack: The master
virtualization engine is unable to detect the
partner virtualization engine’s IP address.

Check the Ethernet connection between
the two virtualization engines.

70030

The SAN configuration was changed by the SAN
Builder.

No action is needed.

70040

The zoning configuration of the host has
changed.

No action is needed.

70050

A multipath drive failover occurred.

Check the multipath drive.

70051

A multipath drive failback occurred.

No action is needed.

70098

Instant copy degraded.

If no spare is available, replace the failed
drive with a new drive.

70099

Degrade because the drive has disappeared.

Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.

7009A

A mirror drive was written to, causing it to enter
the read degrade state.

Reinsert the missing drive, or replace it
with a drive of equal or greater capacity.

7009B

A drive entered the write degrade state.

Reinsert the drive (if good) or replace it if
it is defective.

7009C

During a rebuild, the last primary drive failed.
This is a very rare multipoint failure.

1. Backup the drive data.
2. Destroy the mirror drive where the

failure has occurred.

3. Format the drives using mode 14.
4. Create a new mirror drive.
5. Reassign the old SCSI ID and LUN to

the new mirror drive.

6. Restore the data.

71000

Communication has been recovered between the
two virtualization engines.

No action is needed.

TABLE A-1

SRN Reference

SRN

Description

Corrective Action