Switch error messages, Reset the switch, Rerun the appropriate switch command – Sun Microsystems 6900 User Manual

Page 188: Re-run the switch command, Table b-2, Sun proprietary/confidential: internal use only

Advertising
background image

168

Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Switch Error Messages

TABLE B-2

Sun StorEdge Network FC Switch Error Messages

Source of Error Message

Cause of Error Message

Suggested Corrective Action

Common to all Sun
StorEdge network FC
switches

The Sun StorEdge system type
entered (

${cab_type})

does not

match the system type discovered
(

${boxtype

}).

Either call the command with the

-f force

option to force the series

type, or do not specify the cabinet
type (no

-c

option).

Common to all Sun
StorEdge network FC
switches

The switch is unable to obtain a lock
on switch

${switch}

. Another

command is running.

1. Check

listavailable -s

to see

if another switch command might
be updating the configuration.

2. If the switch in question does not

appear, check for the existence of
the lock file directly by typing

ls

-la /opt/SUNWsecfg/etc

(look

for .

switch.lock

).

3. If the lock is set in error, use the

removelocks -s

command to

clear it.

Due to a non-reentrant interface, there
is a single lock file for all switches.
Only one can be accessed at a time.

Common to all Sun
StorEdge network FC
switch commands

Unable to determine switch type.
Interface may be down or type is
unsupported.
The switch commands now have to
be able to determine if the switch is a
1 Gbit or 2 Gbit switch, and they
were unable to obtain the flash
revision on the switch for some
reason.

1. Reset the switch.
2. Rerun the appropriate switch

command.

Common to all Sun
StorEdge network FC
switch commands

Invalid login id and/or password
entered.

The user has set a login id and
password on the 2Gbit switch.

1. Set the

SWLOGIN

and

SWPASSWD

environment variables to the
correct switch login id and
password.

2. Re-run the switch command.