Tableb3 sun storedge t3+ array error messages, Replace the failed frus, Table b-3 – Sun Microsystems 6900 User Manual

Page 191: Sun proprietary/confidential: internal use only

Advertising
background image

Appendix B

Configuration Utility Error Messages

171

Sun Proprietary/Confidential: Internal Use Only

Sun StorEdge T3+ Array Partner Group
Error Messages

Caution –

Running

restoret3config

(1M) or

modifyt3config

(1M) destroys all

data on the Sun StorEdge T3+ array

.

TABLE B-3

Sun StorEdge T3+ Array Error Messages

Source of Error Message

Cause of Error Message

Suggested Corrective Action

Common to Sun
StorEdge T3+ array

• The current configuration does not
match the reference (standard)
configurations.
• This particular configuration is not
a standard, supported type.

1. Check the current Sun StorEdge

T3+ array configuration with the

showt3 -n <t3>

command.

2. Verify whether the configuration

is corrupted or has changed.

3. Refer to the

raid.cfg

files in

/opt/SUNWsecfg/etc

to

determine if the configuration
commands are set up and
functioning properly.

Common to Sun
StorEdge T3+ array

• Could not mount volume

$vol

ume

$lun

config does not match

• The LUN might have multiple
drive failures or corrupted data or
parity.

1. Replace the failed FRUs.
2. Restore the Sun StorEdge T3+

array configuration with the

restoret3config -f -n

t3_name

command.

Common to Sun
StorEdge T3+ array

• No volumes exist on this Sun
StorEdge T3+ array.

$volume volume

not found on

this Sun StorEdge T3+ array.

Create and restore the Sun StorEdge
T3+ array LUNs using

restoret3config

(1M) or

modifyt3config

(1M).

Common to Sun
StorEdge T3+ array

• The

$fru

status is not ready or

enabled.
• Operations on the Sun StorEdge
T3+ array are being aborted.

The disk, controller, or loop interface
card in the Sun StorEdge T3+ array
might be faulty. Replace the failed
FRU and rerun the utility.