Sun proprietary/confidential: internal use only, Chapter 2 general troubleshooting procedures 13 – Sun Microsystems 6900 User Manual

Page 33

Advertising
background image

Chapter 2

General Troubleshooting Procedures

13

Sun Proprietary/Confidential: Internal Use Only

FIGURE 2-3

Primary Data Paths to the Master Sun StorEdge T3+ Array

To access the LUN on the alternate master, the Sun StorEdge T3+ array I/O could
travel:

From HBA-0 -> switch -> virtualization engine(1) -> switch -> alternate master
controller (primary route from HBA-0)

From HBA-0 -> switch -> virtualization engine(1) -> switch -> switch -> master
controller -> backend loop to alternate master (secondary route from HBA-0)

From HBA-1 -> switch -> virtualization engine(2) -> switch -> switch -> alternate
master controller (primary route from HBA-1)

From HBA-1 -> switch -> virtualization engine(2) -> switch -> master controller -
> backend loop to alternate master (secondary route from HBA-1)

Host with HBA-0 and HBA-1

LUN0 - 10G

Active-MPDrive0

LUN1 - 10G

Active-MPDrive1

Switch

Virtualization

Engine (2)

Switch

LUN0 - 500G

Active-Master

LUN1 - 500G

Passive -

Alternate Master

Logical Multipath Drive

MPDrive 0

Logical Multipath Drive

MPDrive 1

T3ES

(Master)

(0A - 1P)

(Alternate Master)

(1A - 0P)

LUN0 - 10G

Active-MPDrive0

LUN1 - 10G

Active-MPDrive1

Switch

Virtualization

Engine (1)

Storage I/O and

Virtualization Engine Communications Traffic

SAN

Database

MPDrive

Carved LUNs

Masking

LUN0 - 500G

Passive - Master

LUN1 - 500G

Active -

Alternate Master

Switch

Advertising
This manual is related to the following products: