To put the c2 path back into production, Type, Verify that i/o has resumed on all paths – Sun Microsystems 6900 User Manual

Page 39: To put the

Advertising
background image

Chapter 2

General Troubleshooting Procedures

19

Sun Proprietary/Confidential: Internal Use Only

Note –

To confirm that a failover is occurring, open a Telnet session to the Sun

StorEdge T3+ array and check the output of

port listmap

.

Another, but slower, method is to run the

runsecfg

script and verify the

virtualization engine maps by polling them against a live system.

Caution –

During the failover, small computer systems interface (SCSI) errors will

occur on the data host and a brief suspension of I/O will occur.

To Put the

c2

Path Back into Production

1. Type:

2. Verify that I/O has resumed on all paths.

# cfgadm -c configure

c2::2b000060220041f4

Advertising
This manual is related to the following products: