Sanyo CH4242 User Manual

Page 12

Advertising
background image

11

S4359146

9

9

9

9

9

SC

1

1

1

1

1

X

8

8

8

8

8

WT

7

7

7

7

7

RC

(WL)

5

5

5

5

5

C

4

4

4

4

4

U

3

3

3

3

3

T

2

2

2

2

2

K

6

6

6

6

6

RC

(WD)

Out-
door
unit

Heat source

Hot air

Exhaust fan

0591_C_I

Outdoor Unit

AVOID:

heat sources, exhaust fans, etc. (Fig. 2-1)

damp, humid or uneven locations.

DO:

choose a place as cool as possible.

choose a place that is well ventilated and outside

air temperature does not exceed maximum 115

°

F

constantly.

allow enough room around the unit for air intake/

exhaust and possible maintenance. (Fig. 2-2)

provide a solid base; about 6 inch above ground

level to reduce humidity and possible water damage

in the unit and decreased service life. (Fig. 2-3)

use lug bolts or equivalent to bolt down unit,

reducing vibration and noise.

In case of multiple installations

Fig. 2-1

Fig. 2-2

Min.
1 inch

Min.
1 inch

Min. 2 ft.

4 in.

0931_C_I

Min.
7 ft.

Ground

Air
dis-
charge

0932_C_I

Obstacle above

Unit spacing if air discharge chamber is not used.

Unit spacing when air discharge chamber is used.

Min. 4 ft.

Min. 4 ft.

Min. 5 ft.

Min. 1 ft.

Min. 12 ft.

Min. 8 inch

Min. 4 ft.

Min. 8 inch

Min. 4 ft.

Min. 1 ft. 2 inch

Min. 1 ft. 2 inch

Min. 1 ft.

Min. 1 ft.

Air
discharge
chamber

If you would like to make the separation smaller on the air
discharge side, use an air discharge chamber.
You can install any number of units side-by -side.

Only up to 3 units can be installed side-by-side under the above
conditions. The next group must be spaced at least 1 ft. away
from the first group.

0933_C_S

Fig. 2-3

Air in

Air in

Air
discharge

Concrete block
4 inch

×

1 ft. 4 inch

beams or equal

Anchor bolts
(4 pieces)

Min. 6 inch

0934_C_I