One hole is required for the air conditioner tubing, and

may be either on the left or right side. (Also see sec-

tion 3-14. Preparing the Indoor Side Tubing.)

(1)

Tape the full-scale installation diagram on the

wall at the location selected. Make sure the unit is

horizontal, using a level or tape measure to

measure down from the ceiling. (Fig. 3-24)

(2)

Determine if the hole is to be drilled at the left or

right hole location.

(3)

Before drilling a hole, check that there are no

studs or pipes behind the determined location.

Avoid area where electrical

wiring or conduit is located.

Also take this precaution if

the tubing goes through a

wall at any other location.

(4)

Using a sabre saw, key hole saw or 3-5/32 in.

hole-cutting drill attachment, make a hole in the

wall. The required minimum hole diameter for

these models is 3-3/16 in. (Fig. 3-25)

(5)

Measure the thickness of the wall from the inside

edge to the outside edge and cut PVC pipe at a

slight angle 1/4 in. shorter than the thickness of

the wall. (Fig. 3-26)

(6)

Place the plastic cover over the end of the pipe,

(for indoor side only) and insert in the wall.

(Fig. 3-27)

Hole should be made at a slight downward slant to the

outdoor side.

NOTE

Indoor
side

Outdoor
side

0066_T_I

Cut at slight angle

PVC pipe (locally purchased)

0941_T_I

Plastic
cover

INSIDE

Wall

Slight
angle

PVC pipe

OUTSIDE

0942_K_I

Tape

1354_T_I

Full scale
installation diagram

CAUTION

KH3642

Fig. 3-24

Fig. 3-25

Fig. 3-26

Fig. 3-27