5-3. Wiring System Diagrams

(1)

Basic wiring diagram for standard control

1

2

U1

U2

1

2

1

2

1

2

1

2

G

G

L1

L2

G

Indoor Unit

Inter-unit
power wiring
Single phase
230/208V

Inter-unit
control wiring
(Low voltage)

Remote controller

Outdoor Unit

Ground

Ground

(Option)

B

D

A

2085_M_I

Power supply
Single phase
230/208V

R.C. Address on the PCB: 0 (S2, BLK)
(0: Factory shipped state)

L1

L2

U1

U2

0

C

*Remote controller wirings are wire joint connection.

NOTE

(1)

Refer to Section 5-2. “Recommended Wire

Length and Wide Diameter for Power Supply

System” for the explanation of “A”, “B”, “C”, “D”,

and “E”, in the above diagrams.

(2)

Inter-Unit Control Wiring (C) and remote control-

ler wiring (D), (E) has no polarity.

But for other wiring, respect polarity.

Be sure to connect as shown in the Wiring

System Diagram.

(3)

R.C. Address should be set before turning the

power on.

(4)

Regarding the R.C. Address setting, refer to

page 87. Auto. address setting can be executed

by a remote controller automatically.

G

L2

L1

1 2

Power
supply

5P terminal board + 2P terminal board

2086_M_I

CH Type

U1

Inter-unit

control wiring

Inter-unit

power wiring

U2

1

2

Inter-unit

power wiring

U1

Inter-unit

control wiring

U2

5P terminal board

2087_M_I

XH, TH, UH Type

Inter-unit

control wiring

4P terminal board

2088_M_I

1

2

Inter-unit

power wiring

U1 U2

KH Type

3003_M_I

Remote

controller wiring

3003_M_I

Remote

controller wiring