7-11. Misoperation Alarm Indicators

Alarm indicator lamps on the indoor unit indicate the

error cause when the air conditioner fails to operate

upon being switched on. The possible alarm indica-

tions are given in Table 7-1. Fig.7-12 shows the

location of the alarm lamps on the indoor unit. (See

Table 7-1, Fig. 7-12)

Alarm

(OPERATION

(TIMER

(STANDBY

Cause of Trouble

lamp)

lamp)

lamp)

O

S.C. errors* between the indoor unit’s controller (PCB) and the remote

controller.

O

Compressor protector is working.

O

S.C. errors between indoor and outdoor units.

O

O

Indoor or outdoor thermistor is malfunctioning.

O

O

Outdoor unit protector is working.

O

O

Indoor unit protector is working.

O

O

O

TEST RUN switch on the operation controller is in ON state.

NOTE

Stick the alarm message label accompanying with the

wireless remote controller on the electrical component

box to find the cause of trouble in case of need.