S4359146

10-7. Taping the Tubes

(1)

At this time, the refrigerant tubes (and electrical

wiring if local codes permit) should be taped with

armoring tape in 1 bundle. To prevent the con-

densation from overflowing the drain pan, keep

the drain hose separate from the refrigerant

tubing.

(2)

Wrap the armoring tape from the bottom of the

outdoor unit to the top of the tubing where it

enters the wall. As you wrap the tubing, overlap

half of each previous tape turn. (Fig. 10-10)

(3)

Clamp the tubing bundle to the wall, using 1

clamp about every 3 feet.

Do not wind the armoring tape too tightly since this will

decrease the heat insulation effect. Also ensure that

the condensation drain hose splits away from the

bundle and drips clear of the unit and the tubing.

10-8. Finishing the Installation

After finishing insulating and taping over the tubing,

use sealing putty to seal off the hole in the wall to

prevent rain and draft from entering. (Fig. 10-11)

Fig. 10-10

Tubing

Apply putty here

0137_C_I

Fig. 10-11

NOTE

Insulated tubes Drain hose

Clamp

1124_M_I