44

S4359146

Loose wiring may cause the

terminal to overheat or result

in unit malfunction. A fire

hazard may also exist.

Therefore, ensure that all

wiring is tightly connected.

When connecting each power wire to the correspond-

ing terminal, follow the instructions on “How to connect

wiring to the terminal” and fasten the wire securely with

the fixing screw of the terminal plate.

5-4. How to Connect Wiring to the Terminal

For stranded wiring

(1)

Cut the wire end with a wire cutter or wire-cutting

pliers, then strip the insulation to expose the

stranded wiring about 3/8 in.. (Fig. 5-1)

(2)

Using a Pillips head screwdriver, remove the

terminal screw(s) on the terminal plate.

(3)

Using a ring connector fastener or pliers, securely

clamp each stripped wire end with a ring pressure

terminal. (Fig. 5-1)

(4)

Place the ring pressure terminal, and replace and

tighten the removed terminal screw using a

screwdriver. (Fig. 5-2)

Wire

Special
washer

Screw

Ring pressure
terminal

Terminal plate

Screw and
Special washer

Ring
pressure
terminal

Wire

1107_M_I

Fig. 5-2

Fig. 5-1

Stranded wire

Ring
pressure
terminal

Strip 3/8 in.