The following shows the transition conditions from subset

A to subset B.

1.

Input a character code unique to subset B (60H

to 7FH) when subset A is selected.

2.

Then input a character code unique to subset B

(60H to 7FH) without inputting a character code

unique to subset A (00H to 1FH). (If a character

code unique to subset A is input in this step,

subset B is not selected. The character code

unique to subset B input in step 1 is expressed

with the shift code.)

The following shows the transition conditions from subset

B to subset A.

1.

Input a character code unique to subset A when

subset B is selected.

2.

Then input a character code unique to subset A

without inputting a character code unique to

subset B. (If a character code unique to subset B

is input in this step, subset A is not selected. The

character code unique to subset A input in step 1

is expressed with the shift code.)

Subset C is selected when four continuous character codes

(30H to 39H) are input.

If a code common to subset A and subset B is input when a

subset is not determined or subset C is selected, subset B is

temporarily selected.