A-21 – Sun Microsystems 5602 User Manual

Page 241

Advertising
background image

A – Command Line Interface

Set Config Command

59097-01 A

A-67

0

threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its triggers, and sampling window one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the

”Config Command” on page A-16

for information about saving

and activating a configuration.

Table A-21

describes the Set Config Threshold

parameters. The switch will down a port if an alarm condition is not cleared within
three consecutive sampling windows (by default 30 seconds). Reset the port to
bring it back online. An alarm is cleared when the threshold monitoring detects
that the error rate has fallen below the falling trigger.

Table A-21. Set Config Threshold Parameters

Parameter

Description

Threshold Monitoring Enabled

Master enable/disable parameter for all
events. Enables (True) or disables (False)
the generation of all enabled event alarms.
The default is False.

CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled

The event type enable/disable parameter.
Enables (True) or disables (False) the
generation of alarms for each of the
following events:

„

CRC errors

„

Decode errors

„

ISL connection count

„

Device login errors

„

Device logout errors

„

Loss-of-signal errors

Rising Trigger

The event count above which a rising
trigger alarm is logged. The switch will not
generate another rising trigger alarm for
that event until the count descends below
the falling trigger and again exceeds the
rising trigger.

Falling Trigger

The event count below which a falling
trigger alarm is logged. The switch will not
generate another falling trigger alarm for
that event until the count exceeds the
rising trigger and descends again below
the falling trigger.

Sample Window

The period of time in seconds in which to
count events.

Advertising