A – Command Line Interface

Set Config Command

59097-01 A

A-73

0

The following is an example of the Set Config Threshold command:

SANbox Manager #> admin start

SANbox Manager (admin) #> config edit

SANbox Manager (admin-config) #> set config threshold

A list of attributes with formatting and current values will follow.

Enter a new value or simply press the ENTER key to accept the current value.

If you wish to terminate this process before reaching the end of the list

press 'q' or 'Q' and the ENTER key to do so.

ThresholdMonitoringEnabled (True / False) [False ]

CRCErrorsMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [25 ]

FallingTrigger (decimal value, 0-1000) [1 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

DecodeErrorsMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [200 ]

FallingTrigger (decimal value, 0-1000) [0 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

ISLMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [2 ]

FallingTrigger (decimal value, 0-1000) [0 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

LoginMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [5 ]

FallingTrigger (decimal value, 0-1000) [1 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

LogoutMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [5 ]

FallingTrigger (decimal value, 0-1000) [1 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

LOSMonitoringEnabled (True / False) [True ]

RisingTrigger (decimal value, 1-1000) [100 ]

FallingTrigger (decimal value, 0-1000) [5 ]

SampleWindow (decimal value, 1-1000 sec) [10 ]

Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.