A-25 – Sun Microsystems 5602 User Manual

Page 259

Advertising
background image

A – Command Line Interface

Set Setup Command

59097-01 A

A-85

0

snmp
Prompts you in a line-by-line fashion to change SNMP configuration settings.

Table A-25

describes the SNMP fields. For each parameter, enter a new value or

press the Enter key to accept the current value shown in brackets.

Table A-25. SNMP Configuration Settings

Entry

Description

SNMPEnabled

Enables (True) or disables (False) SNMP on the switch. The
default is True.

Contact

Specifies the name of the person to be contacted to respond to
trap events. The name can be up to 64 characters excluding #,
semicolon (;), and comma (,). The default is undefined.

Location

Specifies the name of the switch location. The name can be up
to 64 characters excluding #, semicolon (;), and comma (,).
The default is undefined.

Trap [1-5] Address

Specifies the workstation IP address to which SNMP traps are
sent. The default address for trap 1 is 10.0.0.254. The default
address for traps 2–5 is 0.0.0.0. Addresses, other than 0.0.0.0,
for all traps must be unique.

Trap [1-5] Port

Specifies the workstation port to which SNMP traps are sent.
Valid workstation port numbers are 1–65535. The default is
162.

Trap [1-5] Severity

Specifies the severity level to use when monitoring trap events.
The default is Warning.

Trap [1-5] Version

Specifies the SNMP version (1 or 2) to use in formatting traps.
The default is 2.

Trap [1-5] Enabled

Specifies whether traps (event information) are enabled or
disabled (default).

ReadCommunity

Read community password that authorizes an SNMP agent to
read information from the switch. This is a write-only field. The
value on the switch and the SNMP management server must
be the same. The read community password can be up to 32
characters excluding #, semicolon (;), and comma (,). The
default is “public”.

WriteCommunity

Write community password that authorizes an SNMP agent to
write information to the switch. This is a write-only field. The
value on the switch and the SNMP management server must
be the same. The write community password can be up to 32
characters excluding #, semicolon (;), and comma (,). The
default is “private”.