A – Command Line Interface
Set Config Command

A-68

59097-01 A

0

zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.

Table A-22. Set Config Zoning Parameters

Parameter

Description

InteropAutoSave

Available only when the InteropMode parameter is Standard, this
parameter enables (True) or disables (False) the saving of
changes to active zone set in the switch’s permanent memory.
Refer to

”InteropMode” on page A-66

. The default is True.

Disabling the Autosave parameter can be useful to prevent the
propagation of zoning information when experimenting with
different zoning schemes. However, leaving the Autosave
parameter disabled can disrupt device configurations should a
switch have to be reset. For this reason, the Autosave parameter
should be enabled in a production environment.

DefaultVisibility

Enables (All) or disables (None) communication among the
switch’s ports/devices and the fabric in the absence of an active
zone set. The default is All.

DiscardInactive

Enables (True) or disables (False) the discarding of all inactive
zone sets from that zoning database. Inactive zone sets are all
zone sets except the active zone set. The default is False.

Advertising