TROUBLESHOOTING & REPAIR

F-58

F-58

COMMANDER 300

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

POWER MODULE TEST

(continued)

FIGURE F.27 – DIODE MODULE TEST

DIODE MODULES
AND HEAT SINKS

CHECK DIODE MODULE

8. Using the analog ohmmeter, connect the

negative meter probe to the terminal on the
diode module. See Figure F.27. Connect the
positive meter probe to the heat sink. The
resistance should be very high (over 20,000
ohms).

9. Using the analog ohmmeter, connect the

positive meter probe to the terminal on the
diode module. See Figure F.27. Connect the
negative meter probe to the heat sink. The
resistance should be low (approximately
1000 ohms).

10. Reconnect all leads and sheet metal previ-

ously removed.

11. Torque the capacitor nuts to 50-60 inch-

pounds.

Advertising