16. Using the 7/16" wrench, disconnect stator

lead #6 from the auxiliary power stud on the
left side of the control box. See Figure F.48.

17. With the 3/8" wrench, disconnect lead #5

from the center ground stud (nearest the
control transformer). See Figure F.48.

18. Using the phillips screw driver, remove lead

#3 from the top 50A circuit breaker for the
120/240V receptacle. See Figure F.48.

NOTE: This lead must be wound two turns clock-
wise through the toroid (opposite in direction from
lead #6A).

19. Disconnect lead #5A from the auxiliary

power ground stud (left side of the control
box, next to the 120V circuit breaker). See
Figure F.48.

20. Using the 3/8 wrench, remove the two

screws holding the control box to the top of
the fan baffle.