INSTALLATION

F-25

F-25

COMMANDER 300

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SHUTDOWN SOLENOID TEST

(continued)

8

7

6

5

4

3

2

1

9

10

11

12

13

14

15

16

#224(+)

#262(-)

J30

5. Check the shutdown solenoid coil resistance

from lead #224 (8J30) to lead #262 (7J30).
The normal resistance is approximately 3
ohms. If the resistance is not correct, the
coil or the diode that is in parallel with the
coil may be faulty. See the Wiring Diagram.
See Figure F.7.

6. Using the external 12VDC supply apply

12VDC to leads #224(+) and #262(-). See
Figure F.7. CORRECT POLARITY MUST
BE OBSERVED OR DAMAGE TO THE
INTERNAL DIODE MAY RESULT.
See the
Wiring Diagram. The shutdown solenoid
should activate when the 12VDC is applied.
This can be detected by a “clicking” sound.

7. The solenoid should deactivate when the

12VDC is removed.

8. If the solenoid does not activate when the

12VDC is applied the solenoid or internal
diode may be faulty. Replace.

9. Reconnect plug J30 and P30. Replace any

cable ties previously removed.

10. Reassemble the right front case side and

close the engine service access door.

FIGURE F.7 – PLUG J30 PIN/LEAD ASSIGNMENTS