CONTROL INPUT TEST

(continued)

FIGURE F.31 – Plug J3

Pin 7

Plug J3

Pin 8

Pin 16

Pin 14

Pin 5

24. Using a remote control hooked up to the

machine amphenol, set the Local/Remote
switch in the “Remote” position, and the
remote control dial to the minimum position.
Repeat steps 19-21. Remember to include
the RF bypass PC board in the continuity
check.

25. Disconnect the remote control.

26. Using an ohmmeter, measure the resistance

from J3 pin 5 to J3 pin 14. See Figure F.31.
The resistance should decrease from 50K to
0 ohms uniformly as the arc force dial is
turned clockwise from minimum to maximum.

27. If the resistance check in step 26 fails, check

for continuity and poor connections on leads
277, 278, and 278A from the potentiometer
back to the control board. See the Wiring
Diagram. Look closely for broken molex pins.

28. If all leads check ok, the Arc Force poten-

tiometer is bad. Replace.

29. Plug J3 back into the control PC board.

30. If all continuity checks in this section are ok

but the voltage checks from the previous sec-
tion are off, replace the control board.